Product List

KJT-PKG Wiring Cavity Type Deviation Switch
KJT-PKG Wiring Cavity Type Deviation Switch
KJT-PKG Wiring Cavity Type Deviation Switch
KJT-PKG Wiring Cavity Type Deviation Switch

KJT-PKG Wiring Cavity Type Deviation Switch

  • Product Series:KJT-PKG
  • Load current:AC380V 5A,DC24V 5A
  • Contact method:NO1.NC1;NO2. NC2. (Please specify when ordering)
  • Reset mode : Auto
  • Appliance life:>100,000 times
  • Protection class :IP65/IP67

KJT-PK high-end model series are widely used in the detection of conveyor belt deviation to prevent material overflow and other failures 

caused by belt deviation. This machine is widely used in transportation systems in mining, electric power and chemical industries.


When the running tape deviates, the vertical roller on the edge of the tape rotates and squeezes the vertical roller to tilt it. If the tilt of 

the vertical roller is greater than the action angle, a switch signal will be sent immediately. If the vertical roller continues to tilt greater 

than the secondary action angle, a switch signal will be sent. , then output another set of switch signals. The two sets of switch signals 

can be used for alarm or shutdown respectively. After the belt conveyor resumes normal operation, the vertical roller will automatically reset.

1

Product Paramenters
ambient temperature-30℃~+50℃
Relative humidity0~85%
first action angleI:12°;II:10°;III:20°
second action angleI:30°;II:40°;III:35°
Action force70-100N
Number of contacts1 normally open, 1 normally closed (2 groups of normally open and 2 groups of normally closed can be added as needed)
Contact ratingAC380V 5A DC24V 5A
reset mode Auto
Electrical life>100,000 times
Protection levelIP65/IP67
weight5kg

尺寸图

1692416822005   

f85861ea63038614d36f58cc6993550

1692415243909(1)

接线图.png

88


场景图

d25bccef52ed6fc24d8045760301c48